Bug 11133

Summary: RMC: Multiple fingerprints per Board
Product: [Build System, Metadata & Runtime] BSPs Reporter: Mikko Ylinen <mikko.ylinen>
Component: bsps-meta-intelAssignee: Todor Minchev <todor.minchev>
Status: RESOLVED OBSOLETE QA Contact:
Severity: enhancement    
Priority: Medium CC: dmitry.rojkov, sgw
Version: 2.2   
Target Milestone: 2.4   
Hardware: x86   
OS: Multiple   
Whiteboard:
OS type for building Yocto: --- Type of Regression: ---
Verified: Documentation change: No (bug/feature does not impact docs)

Description Mikko Ylinen 2017-03-07 10:36:01 UTC
It seems different BIOS versions for a board may result in different RMC fingerprints. This means the board detection will fail, e.g., if the fingerprint maintained in the database does not match with the BIOS info.

With the current design, the fingerprint-board mapping is 1:1, i.e., for each board there's only one fingerprint. Every time the fingerprint needs to change, either a new copy of the board is needed OR the old fingerprint is updated (and the old versions are no longer supported by the db).

To ease the maintenance problem, each board must be able to store multiple fingerprints (N:1 mapping).
Comment 1 Todor Minchev 2017-05-18 16:36:04 UTC
Does not apply to RMC2. Files can be shared between platforms by creating links between fingerprint directories.