Bug 4827

Summary: runqemu shouldn't hard-code machine knowledge
Product: [Build System, Metadata & Runtime] OE-Core Reporter: Ross Burton <ross.burton>
Component: devtools / tool chainAssignee: Robert Yang <liezhi.yang>
Status: RESOLVED FIXED QA Contact:
Severity: enhancement    
Priority: Medium CC: anibal.limon, bluelightning, edwin.plauchu.camacho, jessica.zhang, liezhi.yang, meta.mr.watcher, meta.watcher, sgw, twoerner
Version: 1.5   
Target Milestone: 2.2 M3   
Hardware: All   
OS: Multiple   
Whiteboard:
OS type for building Yocto: --- Type of Regression: ---
Verified: Documentation change: Don't know
Bug Depends on:    
Bug Blocks: 1018, 1683, 3990, 7459, 7887    

Description Ross Burton 2013-07-08 15:40:40 UTC
There should be some way of putting all of the machine-specific details into configuration files so that runqemu doesn't actually have any machine-specific knowledge.  This way the qemu-zynq and qemu-microblaze details can be in the layer that defines those machines.

(proposing as a 1.6 feature)
Comment 1 Saul Wold 2013-12-02 18:05:20 UTC
Another option from RP: 
(09:55:48 AM) RP: sgw: I'm not sure it has to be a massive rewrite, just adding the ability to search through something like BBPATH for scripts of a given name, source them then have a common function set
Comment 2 Cristian Iorga 2015-07-28 16:27:45 UTC
Investigation started.
Comment 3 Saul Wold 2016-02-10 17:15:31 UTC
Pushing to next release due to change of resources
Comment 4 Ross Burton 2016-04-07 15:39:50 UTC
*** Bug 9411 has been marked as a duplicate of this bug. ***