Bug 6189

Summary: Minnowboard MAX EDKII implementation
Product: [Hardware Platforms] MinnowBoard MAX Firmware Reporter: Stephen K Jolley <sjolley.yp.pm>
Component: minnowmax-edk2Assignee: Divya Mahesh <divya.mahesh>
Status: RESOLVED FIXED QA Contact:
Severity: major    
Priority: High CC: michael.p.krau, sjolley.yp.pm
Version: unspecified   
Target Milestone: Pre-Production Relea   
Hardware: MinnowBoard Max   
OS: x86_64   
Whiteboard:
OS type for building Yocto: --- Type of Regression: ---
Verified: Documentation change: No (bug/feature does not impact docs)

Description Stephen K Jolley 2014-04-18 20:37:34 UTC
Firmware is working this issue.
Comment 1 Stephen K Jolley 2014-04-23 00:30:42 UTC
Can you provide the Frimware team more information
Comment 2 Michael Krau 2014-04-23 22:25:19 UTC
New TXE files were provied to the PSI firmware team.  Test versions of the firmware image were created, and provided for testing.

Results of tests indicate that these files in addition to the Hardware changes made on the Special testing Platform (proto-typical unit), allow the ITP to work on the MInnowBOard MAX.  

Future Firmware images will include these new files.  REV-A1 will also have to include the hardware updates.
Comment 3 Stephen K Jolley 2014-04-24 23:24:27 UTC
The ITP board is working with the newer Firmware images.